Paper check About

High-Performance Lithium Battery Anodes Using Silicon Nanowires

2008 · paper · Materials

Supporting methods for lithium battery anodes made of silicon nanowires grown directly on stainless steel. They describe nanowire growth, electrochemical testing, electron microscopy and X-ray characterization, and electrical measurements on single nanowires. No results are given in the text shown.

Checked: PDF from media.springernature.com, fetched 4 Oct 2026. Page numbers are those of that PDF.

0 findings

None that passed a second check.

3 minor (typos and the like; most checked by the judge only)
Typo Microbalance manufacturer printed as "microbalance (Sartarious SE2, 0.1 μg resolution)"; the maker's name is presumably spelled "Sartorius".
  • p. 1 Materials and Methods, first paragraph
    Sartarious SE2, 0.1 μg
  • p. 1
    using a microbalance (Sartarious SE2, 0.1 μg resolution)
  • p. 1 Materials and Methods, SiNW mass
    Sartarious SE2
  • p. 1
    microbalance (Sartarious SE2, 0.1 μg

Only the authors can say what is right here.

Judge's note: Rests on outside knowledge: the SE2 microbalance is made by a company spelled 'Sartorius'. The crop of page 1 (Materials and Methods) shows 'Sartarious SE2, 0.1 μg resolution' exactly as printed, so this is not an extraction artefact. It is a cosmetic misspelling of a proper name.

Second check: another model agreed

Report a problem with this finding
Typo "confirmed by XRD)" is used on page 2 before the abbreviation is defined; the term is then written "x-ray diffraction (PANalytical X'Pert" with no abbreviation and lower-case x, and only defined at the third mention, "X-ray diffraction (XRD)" (pages 2-3).
  • p. 2 Materials and Methods, top of page
    confirmed by XRD)
  • p. 2 Materials and Methods, characterization paragraph
    x-ray diffraction (PANalytical X’Pert
  • p. 3 Materials and Methods, top of page
    ray diffraction (XRD), samples were placed

Judge's note: Checked the page 2 and page 3 images. The order is as described: XRD undefined at the top of page 2, "x-ray diffraction" lower-case and unabbreviated in the characterization paragraph, then "For X-ray diffraction (XRD)" across the page 2/3 break. The same paragraph also prints "energy dispersive X-ray spectrometer" with a capital X, so the capitalisation is inconsistent within the document. Meaning is unaffected and XRD is a universally understood abbreviation; this is a house-style point only.

Second check: none (judge only)

Report a problem with this finding
Typo Figure S1 caption reads "Cyclic voltammagram (CV)"; the word is "voltammogram".
  • p. 3 Figure Captions, Figure S1
    Cyclic voltammagram (CV)
  • p. 3
    Figure S1. Cyclic voltammagram (CV) of a 75 nm

Judge's note: The page 3 image shows "Figure S1. Cyclic voltammagram (CV) of a 75 nm Au film", so it is not an extraction artefact. The document spells the related term "cyclic voltammetry" correctly on page 2. A plain misspelling of an ordinary technical word with an evident fix.

Second check: another model agreed

Report a problem with this finding
Something wrong with this page, or a finding we missed?